Battery chargers - NRG Hi Power
• Three stage IUoU battery charging.
• Multiple outputs in order to charge more groups of batteries (internal bat-
tery isolator diodes).
• Differentiated charging for liquid electrolite or gel batteries.
• Integrated fuses inside the battery chargers (one for each output).
• Thermal battery protection (with optional sensors).
• Ability of providing full output power with low supply voltage.
• The possibility of using the battery charger as a power supply without bat-
teries.
• Low residual fluctuation on output (ripple lower than 30 mV RMS).
• Universal AC supply input (FR models - SBC 1450 ADV and SBC 1950 ADV
escluded).
• Compatible with every kind of generator.
• Capable of operating in a wide range of ambient temperatures.
• Variable speed for the cooling fan.
• High-technology control panel.
• Automatic and manual half power mode (with optional RCM 1620).
• CAN BUS interface for data transfer.
• Current sharing (only HI-Power)
Protections
• Reverse polarity (with internal fuses)
• Overload
• Output short circuit
• Overvoltage in output
• Overheating
• Battery overtemperature (optional sensors)
• Multiple outputs in order to charge more groups of batteries (internal bat-
tery isolator diodes).
• Differentiated charging for liquid electrolite or gel batteries.
• Integrated fuses inside the battery chargers (one for each output).
• Thermal battery protection (with optional sensors).
• Ability of providing full output power with low supply voltage.
• The possibility of using the battery charger as a power supply without bat-
teries.
• Low residual fluctuation on output (ripple lower than 30 mV RMS).
• Universal AC supply input (FR models - SBC 1450 ADV and SBC 1950 ADV
escluded).
• Compatible with every kind of generator.
• Capable of operating in a wide range of ambient temperatures.
• Variable speed for the cooling fan.
• High-technology control panel.
• Automatic and manual half power mode (with optional RCM 1620).
• CAN BUS interface for data transfer.
• Current sharing (only HI-Power)
Protections
• Reverse polarity (with internal fuses)
• Overload
• Output short circuit
• Overvoltage in output
• Overheating
• Battery overtemperature (optional sensors)
Art.-No. | ||
nominal voltage | 12 V | 12 V |
Number of outputs | 3 | 3 |
supply voltage | 83 V - 264 V, 45 - 66 Hz (automatic switch over) | |
for Battery capacity | 360 - 600 Ah | 450 - 1000 Ah |
max. current output | 80 A | 100 A |
absorption charge voltage | 14,1 V | 14,1 V |
float charge voltage | 13,4 V | 13,4 V |
max. absorption 230 V | 5,4 A | 6,5 A |
max. absorption 120 V | 10,6 A | 12,7 A |
weight | 4,2 kg | 4,2 kg |
Short URL: http://lindemann.kg/s/6/QpI
All article numbers marked in blue can be ordered.
All prices are recommended retail prices in Euro - currency incl. German VAT
All technical specifications are without obligation; errors excepted.
Deliveries exclusively via marine retailers.